The best Side of attune flow cytometer
The best Side of attune flow cytometer
Blog Article
At that time, the early indicators were being dismissed as particles, although the retrospective analysis shown shared qualities Along with the problematic cells in culture. Tracing the an infection helped the lab establish further laboratory methods for screening and security of assay-important mobile strains.
As samples are obtained over the Attune CytPix Flow Cytometer, the large-pace brightfield camera captures and outlets photographs of detected occasions at a level nearly six,000 images for each 2nd, depending on the flow charge and impression dimension. For increased versatility, Attune Cytometric Software allows you to adjust the impression seize frequency as required and choose a particular gate for graphic seize, if needed.
(B) RAW 264.7 macrophages are frequently annotated inaccurately with regard to particle depend because of their complexity and noncircular borders. The quantity of singlets accessible for analysis increases once the person trains and employs a more exact model.
The award-profitable Invitrogen Attune CytPix Flow Cytometer combines acoustic concentrating using a large-speed brightfield digicam for simultaneous superior throughput flow cytometry and higher resolution brightfield imaging.
"A picture isn't really very worth 1000 dots, nonetheless it truly helps to see images. It is excellent to check out illustrations or photos that correlate with staining. One example is, AnnexinV-optimistic cells which have been morphologically distinct than healthful cells, or CD14+ monocytes which have been greater and more textured than CD3+/CD4+/CD14- lymphocytes.
Here, an experienced consumer has gated singlets confidently. Following analyzing the handbook singlet gate, the CytPix picture-derived parameter ParticleCount reveals this gate consists of more than four% aggregates.
Pair your Attune flow cytometer using an autosampler for elevated workflow performance, and add robotic integration for maximum throughput.
Regular graphic excellent even at significant throughput Acoustic focusing plus a higher-velocity digicam Mix to graphic these T cells persistently at small or superior flow prices. Quickly alter aim and camera settings to fulfill experimental needs.
Early indications of this contamination experienced to begin with been dismissed as particles. Backgating to find out new populations. Backgating imaged cells over the Attune CytPix Flow Cytometer also lets you use morphological attributes to find out interesting subpopulations that might not be obvious from flow cytometry information by yourself.
Customers can look at event images in serious-time to verify sample top quality, enhance protocols, and history the morphology of every mobile populace determined for Examination. Imaging capture also Positive aspects from acoustic focusing, which helps to posture the cells to ensure a sharp, centered graphic is attained.
AI-pushed automatic graphic Examination Along with the Attune Cytometric Computer software translates event characteristics into distinctive morphology parameters which might be coupled with conventional fluorescence and scatter parameters to reveal really reproducible inhabitants changes and unique subsets.
We Earlier demonstrated the strength of imaging Auto-T/Ramos cell interactions. Permit’s look at just the inhabitants of biggest curiosity, the double constructive gatherings, to learn more. We will now use prolonged morphological parameters (in this article, circularity and skewness of intensity) to further more analyze the features of these populations and refine gating on these events, escalating info robustness.
Leverage the power of advanced technologies and innovation to speed up your discoveries. Trust inside the Attune Flow Cytometer family to deliver the reliability, pace, and accuracy that set your get the job done apart.
No wash/no lyse leukocyte Assessment with imaging. Cells have been acquired from 24-hour-previous blood by dilution in 1 mM EDTA ( Specialist UX/UI permits users to educate AI models for expanded programs. (A) The “Teach Product” feature delivers annotation tools and genuine-time product instruction accuracy.
At the guts of each Attune Flow Cytometer lies our innovative acoustic concentrating technologies, which utilizes seem waves to meticulously align cells inside the flow mobile. This innovative tactic surpasses conventional hydrodynamic methods, resulting more info in quicker processing speeds, Remarkable information high-quality, and improved sample throughput.
The Attune Xenith cytometer is a high-parameter spectral analyzer, giving both equally spectral unmixing and traditional flow capabilities for in depth and multipurpose mobile analysis.
The Attune CytPix Flow Cytometer enables customers to visualise samples for the duration of acquisition, validate the accuracy of gating methods, and assist outcomes with dependable documentation for publication functions.
What gave the impression to be a homogeneous inhabitants is really much more numerous—an insight that should be thought of when interpreting results.